超高速液相色谱-质谱联用法测定纺织品中6种荧光增白剂Determination of Six Fluorescent Whitening Agents in Textile by Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry
曾立平,沈锦玉,姚汉强
ZENG Li-ping,SHEN Jin-yu,YAO Han-qiang
摘要(Abstract):
建立了纺织品中6种荧光增白剂(FWAs)的超高效液相色谱-质谱-质谱(UPCL-MS-MS)测试法。该方法以三氯甲烷-甲醇(体积比8∶2)为溶剂,二次超声前处理,流动相为乙腈-2.5 mmol/L乙酸胺溶液(p H=5.0),采用串联质谱ESI正模式电离,多反应监测(MRM)模式检测。试验结果表明:该方法能将6种FWAs有效分离,且线性关系较好,线性相关系数均在0.998 4以上,检出限为0.01~0.15 mg/L。方法的平均回收率为89.5%~102.3%,相对标准偏差为1.5%~3.7%。该方法简单、可靠,适用于实际工作中纺织品中FWAs的快速检测。
A method of simultaneous determination of six fluorescent whitening agents(FWAs) in texiles bya ultra-high performance liquid chromatography tandem mass spectrometry(UPCL-MS) was set up. Thesamples were extracted by ultrasonic extraction with trichloromethane-methanol. The analysis was carriedout in a teversed-phase BEH C18 column by gradient elution with acetonitrile-2.5 mmol/L acetate(pH=5.0) as mobile phase. Electrospray ionization mass was operated in the positive mode(ESI~+) using multiplereaction monitoring(MRM).The simulation showed that it could effectively separate the 6 kinds of FWAs,the calibration cuves for the method were linear,the detection limits varied from 0.01 to 0.15 mg/L and thelinear correlation coefficients was higher than 0.9984,the average recoveries were from 89.5% to 102.3%,the relative standard deviation was from 1.5% to 3.7%. The method was accurate,rapid and adapt to the de-termination of the FWAs in textile.
关键词(KeyWords):
荧光增白剂;超声萃取;超高效液相色谱-质谱联用;检测
fluorescent whitening agent;ultrasonic extraction;ultra-high performance liquid chromatography tandem mass spectrometry;test
基金项目(Foundation): 浙江省质量技术监督系统科研计划项目(20150253)
作者(Author):
曾立平,沈锦玉,姚汉强
ZENG Li-ping,SHEN Jin-yu,YAO Han-qiang
DOI: 10.16090/j.cnki.hcxw.2017.03.013
参考文献(References):
- [1]孙海洋,张健飞,巩继贤,等.纺织用荧光增白剂的研究与应用新进展[J].染整技术,2013(3):49-52.
- [2]刘荣琴,高磊红,王未肖,等.紫外分光光度法测定食品包装用纸中的荧光增白剂[J].广州化工,2013(15):135-137.
- [3]穆合塔巴尔·艾地汗木,阿孜古丽·沙吾提.食用菌生产使用荧光增白剂的危害[J].新疆农业科技,2008(3):54-55.
- [4]蒋治国,吴冬梅,培燕钰,等.食用菌中荧光增白剂的风险评估[J]环境与可持续发展,2010(5):47-48.
- [5]河南舒莱卫生用品有限公司.荧光增白剂的使用状况和对人体健康的影响[J].中国卫生标准,2012(4):53-54.
- [6]甘宏宇,薛洁,高敬瑞,等.X-荧光光谱法快速测定荧光增白剂中重金属离子含量[J].染料与染色2013,50(5):56-58.
- [7]CHEN H C,WANG S P,DING W H.Determination of fluorescent wihitening agents in environmental waters by solid-phase extraction and ion pair liquid chromatography-tandem mass spectrometry[J].Journal of Chromatography A,2006,1102(1-2):135-142.
- [8]SANOS M,NERIN C,DOMENO C,et al.The analysis of Fluorescent Whitening Agents Using Reversed-phase HPLC and Mass Spectrometry[J].Lcgc North America,2004,22:550-560.
- [9]汤娟,丁友超,齐琰,等.高效液相色谱/荧光检测法测定纺织品中7种阴离子荧光增白剂[J].分析测试学报,2014,33(9):1032-1037.
- [10]吴钟玲,陈树东,林晓佳,等.高效液相色谱法测定食品接触聚苯乙烯制品中9种荧光增白剂[J].现代食品科技,2013,29(11):2757-2761.
- [11]杜志峰,洗燕萍,刘付建,黄金凤,等.LC-MS/MS法测定发泡塑料餐具中5种荧光增白剂[J].现代食品科技,2013,29(12):3014-3018.
- [12]汤娟,丁友超,曹锡忠,等.超高效合相色谱法快速检测纺织品中的8种荧光增白剂[J].色谱,2014,32(11):1230-1235.
- [13]祝仕清,牛长群,耿亚鹏.UPLC(超高效液相色谱)/MS/MS联用技术测定全血中的西罗莫司[J].中国抗生素杂志,2007,32(6):347-349.
- [14]郭松年,巩泽龙,冯歆轶,等.超高效液相色谱串联质谱法测定婴儿奶粉中的维生素B12[J].化学分析计量,2014,23(6):8-10.